Jackson County |
Code of Ordinances |
Appendix A. UNIFIED DEVELOPMENT CODE |
Article 10. FLOOD DAMAGE PREVENTION |
Division III. PROVISIONS FOR FLOOD HAZARD REDUCTION |
§ 1024. Non-residential construction.
(a)
New construction and/or the substantial improvement of any structure located in A1-30, AE, or AH zones, may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to two feet above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
(b)
A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the public development director as set forth in this article.
(Ord. No. 17-003 , § 1, 10-2-2017)