§ 1175. Stormwater ditches.
Latest version.
All man-made ditches between storm drain pipes and downstream of storm drain pipe shall be designed by a registered professional engineer or landscape architect. The ditch profile and cross-sections every 50 feet shall be shown on the plans. The plans shall show the velocity and flow at each cross-section. Stormwater velocity shall not exceed five fps unless the ditches are lined.
(Ord. No. 17-003 , § 1, 10-2-2017)