§ 1630. Curb and gutter—Detail.  


Latest version.
  • (a)

    Local residential street curbs shall be Portland cement concrete, six-inch x 24-inch x ten-inch vertical or roll back type, with a minimum strength of 3,000 psi at 28 days. For vertical curbing, see standard drawing T-24 in article 23 of this UDC.

    (b)

    Curbs along collectors and local commercial or industrial street curbs shall be Portland cement concrete, six-inch x 24-inch x 12-inch vertical type only, with a minimum strength of 3,000 psi at 28 days.

    (c)

    All curbing shall be backfilled and grassed. The curb and gutter shall be constructed so as to present a smooth, even line both horizontally and vertically. There shall be no areas of ponding.

    (d)

    A valley gutter may be used across a driveway at its intersection with a street. However, valley gutters shall not be allowed across streets at street intersections unless specifically approved by the public development director.

    (e)

    See also standard drawing T-08 in article 23 of this UDC for utility placement with curb and gutter.

(Ord. No. 17-003 , § 1, 10-2-2017)