§ 1653. Sidewalk construction.  


Latest version.
  • (a)

    See standard drawing T-25 in article 23 of this UDC.

    (b)

    Sidewalks must comply with all requirements of the federal Americans with Disabilities Act. See also standard drawing T-29, T-29B, and T-29C in article 23 of this UDC.

    (c)

    Concrete sidewalks shall be a minimum of five feet wide and four inches thick.

    (d)

    Concrete shall be 3,000 psi at 28 days' strength.

    (e)

    Sidewalks shall be backfilled and landscaped.

(Ord. No. 17-003 , § 1, 10-2-2017)