§ 1843. Handrails and guards.  


Latest version.
  • (a)

    Every handrail and guard shall be firmly fastened and capable of supporting nominally imposed loads and shall be maintained in good condition.

    (b)

    Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches above the floor or grade below shall have guards. Handrails shall not be less than 34 inches in height or more than 38 inches in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces.

    (c)

    Guards shall not be less than 36 inches in height above the floor of the landing, balcony, porch, deck, or ramp or other walking surface; provided, however, that guards shall not be required where exempted by the adopted building code.

(Ord. No. 17-003 , § 1, 10-2-2017)