Jackson County |
Code of Ordinances |
Appendix A. UNIFIED DEVELOPMENT CODE |
Article 4. OVERLAY DISTRICTS |
Division III. EAST AND WEST JACKSON CORRIDOR OVERLAY DISTRICTS |
§ 446. Outdoor and street lighting.
(a)
Along the entire property frontage of any new development fronting on and accessing a county road (excludes state routes) in the West Jackson Corridor Overlay District, streetlights shall be required to be installed by the developer at no installation cost to the county consistent with the specifications of this section.
(b)
All parking lot lighting and pedestrian lighting shall meet the specifications of this section.
Lighting Specifications
East and West Jackson Corridor Overlay DistrictsRequirement Streetlights Pedestrian lights Parking lot lights Maximum height (feet) 40 16 35 Minimum height (feet) 35 8 20 Color Black Black Black Pole type Not specified Fluted Fluted Fixture type Cobra head See guidelines Box head Shielding Full cutoff Semi-cutoff, cutoff, or full cutoff Full cutoff Spacing (feet on center) 150 50 Not specified (c)
Security lighting shall be semi-cutoff luminaires. The public development director may limit the number of luminaires remaining activated for security lighting to one-fourth of the total number of each type of luminaire used.
(d)
Permanent mounted exposed exterior neon lights shall not be allowed.
(e)
Roof-mounted lights are not permitted.
(f)
Light fixtures for drive-under canopies shall be recessed into the canopy ceiling so that the bottom of the luminaire does not extend below the ceiling of the canopy.
(Ord. No. 17-003 , § 1, 10-2-2017)