§ 10-51. Residential building construction.
No construction may be initiated within the county for any residential building of any type which:
(1)
Employs a gravity tank-type, flushometer-valve, or flushometer-tank toilet that uses more than an average of 1.6 gallons of water per flush;
(2)
Employs a shower head that allows a flow of more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;
(3)
Employs a urinal that uses more than an average of one gallon of water per flush;
(4)
Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than two gallons of water per minute; or
(5)
Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than 2.5 gallons of water per minute.
(Code 2005, § 14-64)